The Agilent 1260 Infinity Variable Wavelength Detector (VWD) is highly sensitive for HPLC and RRLC analyses. It uses time-programmable wavelength switching so you can optimize the detection sensitivity and selectivity for your specific applications. The latest electronics and refined optics have lowered detector noise levels to below 2.5 µAU. The lowest baseline drift (< 1 x 10-4 AU/h) means you can precisely quantify trace level compounds in samples.
High sensitivity with lowest baseline drift achieved by significant hardware improvements over the most successful predecessor Agilent 1200 Series VWD.Electronic temperature control (ETC) - maximum baseline stability and practical sensitivity under fluctuating ambient temperature and humidity conditions.

New Agilent 1260,Infinity Variable Wavelength HPLC Detector G1314F (VWD)

Details

Description :

New Agilent 1260 Infinity Variable Wavelength HPLC Detector G1314F (VWD) Product Description Highest sensitivity for HPLC and RRLC

The Agilent 1260 Infinity Variable Wavelength Detector (VWD) is highly sensitive for HPLC and RRLC analyses. It uses time-programmable wavelength switching so you can optimize the detection sensitivity and selectivity for your specific applications. The latest electronics and refined optics have lowered detector noise levels to below 2.5 µAU. The lowest baseline drift (< 1 x 10-4 AU/h) means you can precisely quantify trace level compounds in samples.
High sensitivity with lowest baseline drift achieved by significant hardware improvements over the most successful predecessor Agilent 1200 Series VWD.Electronic temperature control (ETC) - maximum baseline stability and practical sensitivity under fluctuating ambient temperature and humidity conditions.
Up to 100% resolution gain in fast LC by 80 Hz data acquisition rate.Wide linear range - for reliable, simultaneous quantification of primary compounds, by-products and impurities.
Stop-flow wavelength scanning for quick wavelength optimization.Radio frequency identification (RFID) technology for flow cells and lamps - a new level of data traceability.
Automatic wavelength verification by built-in holmium oxide filter.Extensive diagnostics, error detection and display with Instant Pilot controller and Agilent Lab Advisor software.
Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn-time with user-settable limits and feedback messages.

Specifications: Agilent 1260 Infinity Variable Wavelength Detector (G1314F)

Detection type Double-beam photometer

Light source Deuterium lamp

Number of signals 1

Maximum data rate 80 Hz

Noise < ± 0.25 x 10 -5 AU, at 230 nm*

Drift 1 x 10-4AU/hr, at 230 nm

Linearity >2.5 AU upper limit

Wavelength range 190-600 nm

Wavelength accuracy ± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter

Slit width 6.5 nm typical over whole wavelength range

Time programmable Wavelength, polarity, peak width, lamp on/off

Flow cells Standard: 14 µL volume, 10 mm cell path length
and 40 bar (580 psi) pressure maximum
High pressure: 14 µL volume, 10 mm cell path length
and 400 bar (5802 psi) pressure maximum
Micro: 2 µL volume, 3 mm cell path length
and 120 bar (1741 psi) pressure maximum
Semi-micro: 5 µL volume, 6 mm cell path length
and 40 bar (580 psi) pressure maximum

Spectral tools Stop-flow wavelength scan

Analog output Recorder/Integrator 100 mV or 1 V, 1 output

Communication LAN, Controller-area network (CAN),
RS-232C, APG Remote: ready
start, stop and shut-down
signals

GLP features Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user settable limits and feedback messages. Electronic records of maintenance and errors. RFID for electronics records of flow cell and UV lamp conditions (path length, volume, product number, serial number, test passed, and usage). Verification of wavelength accuracy with built-in holmium oxide filter.

Safety and maintenance Extensive diagnostics, error detection and display through Agilent Instant Pilot and Agilent Lab Advisor software. Leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. Others Electronic temperature ETC for complete optical unit

Product Tags